Release Notes for NEC Express5800/T120a-E, NEC Express5800/T120a-M
BMC firmware 01.22, SDR 00.10, PIA 01.05  (offline update)
================================================================================
NEC Corporation.
July 2012

[Contents]
1.  About the software
2.  Models and software revisions for update
3.  Installation procedures
4.  Notes
5.  Revision history
6.  Accompanying files
--------------------------------------------------------------------------------

1.  About the software
The NEC Express5800/T120a-M, NEC Express5800/T120a-E BMC firmware update 
module ("the software") supports the following functional enhancement in the 
NEC Express5800/T120a-M, NEC Express5800/T120a-E models:

 - Fixed the issue that the management LAN on Auto Negotiation rarely can not
   communicate.
 - Fixed the issue that the server power sometimes does not turn off by
   using the Force Power Off function from remote access.
 - Fixed the issue that the voltage of VBAT rarely fails. (SDR)

   The following item is functional enhancement when using the server which 
   installed [N8115-03] Remote KVM and Media License

 - Fixed the issue that booting with an ISO image via the remote media
   function sometimes fails.

Note:
  - To prevent a system failure, please read this document carefully and follow 
    the procedure for successful update.  Should your system malfunctions or is 
    powered off due to an unplanned event during update (for example, power 
    blackout or cutoff, lightening, and noise), the system may be damaged and 
    fails to operate normally.  In this case, any remedial measures shall be 
    taken at your expense.

  - To use the management LAN port, you should check the configuration of the
    connection type on the management LAN before updating BMC firmware.
    In the type of Auto Negotiation, you are able to use straight cable or cross
    cable by the function of Auto MDI/MDI-X after updating BMC Firmware.
    In the type of 100 Mbps Full Duplex, 100 Mbps Half Duplex, 10 Mbps Full
    Duplex, or 10 Mbps Half Duplex, you are not able to communicate by the
    function of Auto MDI/MDI-X after updating BMC Firmware.
    However you are able to use straight cable for the destination having MDI-X
    and to use cross cable for the destination having MDI. When you are not able
    to communicate, you and the destination may change to the type of Auto
    Negotiation for using straight cable or cross cable.
    
    How to confirm the connection type on the management LAN
    (1)  Power on the system.
    (2)  When the following message appears, press the F2 key to start the BIOS
         Setup Menu. 
                              "Press <F2> to enter SETUP"
    (3)  Using the arrow keys, move the cursor to [Server]. 
    (4)  Select the [BMC LAN Configuration] sub menu and
    (5)  Then check the [LAN Connection Type] or change the one. 

  - This software does not support to update the BMC firmware by Remote Media
    on EXPRESSSCOPE Engine 2.

2.  Models and software revisions for update 
Users who use the following server models and BMC firmware versions need update:
 - Models to update: 
     1.  NEC Express5800/T120a-E
     2.  NEC Express5800/T120a-M

 - BMC firmware and SDR versions to update:

      - BMC firmware
                        BMC Firmware Revision:  01.11
                        BMC Firmware Revision:  01.14
                        BMC Firmware Revision:  01.19
      - SDR
                        SDR Revision:           00.08x
                        SDR Revision:           00.09x

NOTE:
If your BMC firmware and SDR version are later than the above, you do not 
require the update(the latest versions already include the functions to be 
added by the software).

 - How to confirm your BMC Firmware version:

   - By ESRAS Utility, to confirm your BMC Firmware and SDR version:

(1)  Run the ESRAS Utility.
(2)  Select the [Intelligent Platform Management Interface] sub menu.
(3)  Select the [Management controller information] sub menu.
(4)  Select the [Basbrd Mgmt Ctlr] sub menu.
(5)  The BMC firmware version of your system will be displayed.
(6)  Select the [Repository Information] sub menu.
(7)  The SDR version of your system will be displayed.

   - By BIOS Setup, to confirm your BMC Firmware and SDR version:

(1)  Power on the system.
(2)  When the following message appears, press the F2 key to start the BIOS 
     Setup Menu. 
                              "Press <F2> to enter SETUP"

(3)  Using the arrow keys, move the cursor to [Server]. 
(4)  Select the [System Management] sub menu and press the Enter key. 
(5)  The software versions of your system will be displayed. 
(6)  After confirmation of the software versions, press the ESC key and exit 
     the [System Management] sub menu. 
(7)  Move the cursor to [Exit], using the arrow keys. 
(8)  Select [Exit Discarding Changes], and exit the BIOS Setup Menu. 

   - By ESMPRO Manager Ver.5, to confirm your BMC Firmware and SDR version:

(1)  Run ESMPRO Manager Ver.5.
(2)  After selecting the server, select the [Remote Control] tab.
(3)  Select the [IPMI Information] sub menu.
(4)  Select the [MC(Management Controller) Information] sub menu.
(5)  Select the [Basbrd Mgmt Ctlr] sub menu.
(6)  The BMC firmware version of your system will be displayed.
(7)  Select the [SDR-Management Information] sub menu and press the Enter key.
(8)  The SDR version of your system will be displayed.

    - By EXPRESSSCOPE Engine 2, to confirm your BMC Firmware and SDR version:

(1)  Run EXPRESSSCOPE Engine 2.
(2)  Select the [Information] sub menu.
(3)  Select the [System information] sub menu.
(4)  Select the [Firmware] sub menu.
(5)  The software versions of your system will be displayed.

3.  Installation procedures
- Prepare a CD-R for the update BMC firmware and SDR.

- How to copy the install CD-R:

(1) Download the update module to a desired directory.
(2) Extract the downloaded module to a desired directory.
(3) The software and its installation procedures (readme file) will be
    extracted to that specified folder.
    The folder has "AY012210.iso" and "READMEE.txt".
(4) Write the ISO image file to a CD-R by any CD writing program.
(5) Mark the BMC firmware and SDR versions on the media.

- How to update:

(1) Insert the CD-R into the disk drive of your system, 
    and boot the system from the CD-R.
(2) Automatically update BMC firmware and SDR using the CD-R,
    do not turn off the power until the complete.
(3) After the complete, the following messages are displayed.

    "All programming complete!!"
    "Remove CD-R, enter any key for reset the server."
    
(4) Eject the CD-R and enter any key to boot the system.
(5) Confirm that the BMC firmware Revision has been updated
    to the version listed below.

    BMC Firmware Revision  :  01.22
    SDR Revision           :  00.10
    PIA Revision           :  01.05

4.  Note
- Note after the updated BMC firmware:
(1) Logout all web browser on your system.
(2) Login the web browser on your system if necessary.
     (You need to apply Java 2 Standard Edition Runtime Environment 5.0 
      or later for a Management PC.)

- Note for updating BMC firmware and SDR:
(1) Check the boot sequence of your system in order to boot the disk driver 
    of the CD-R at first.
(2) When the following message appears, check the model and the BMC Firmware 
    version.

    "Error, incorrect server platform found."

5.  Revision history
2012/01/31 BMCFW Revision 01.22, SDR Revision 00.10, PIA Revision 01.05 
 - Fixed the issue that the management LAN on Auto Negotiation rarely can not
   communicate.
 - Fixed the issue that the server power sometimes does not turn off by
   using the Force Power Off function from remote access.
 - Fixed the issue that the voltage of VBAT rarely fails. (SDR)

   The following item is functional enhancement when using the server which 
   installed [N8115-03] Remote KVM and Media License

 - Fixed the issue that booting with an ISO image via the remote media
   function sometimes fails.

2011/05/17 BMCFW Revision 01.19, SDR Revision 00.09, PIA Revision 01.05
 - It supported Op5_Monitor
 - The function which controls each signal of Break,CTS,DCD/DSR from remoteness
   in IPMI SOL(Serial Over LAN) is supported.
 - When using JRE6 Update19 and later version, the Problem that an unsigned 
   applet start-up is blocked by security check is improved.

2010/03/09 BMCFW Revision 01.14, SDR Revision 00.09, PIA Revision 01.05
 - Extended the term of validity for SSL server certificate of EXPRESSSCOPE 
   Engine 2 to ten years.
 - Supported the function of WS-Management.
 - Changed the description of HDD Sensor from "HDD" to "Drive" on "System 
   Environment" of the Web Server function. 
 - Supported the enable/disable function of Auto SEL Clear via command line 
   interface.
 - Improved the STATUS LED to turn amber when CPU or Chipset temperature alarm 
   is detected.
 - "Abnormality of the processor temperature" improves the matter that might be 
    mis-detected uncommonly.
 - "Memory automatically throttled" improves the matter that might be 
   mis-detected uncommonly.
 - Improved not to respond to access via unused port with LAN interface of the 
   EXPRESSSCOPE engine2 
 - Improved EXPRESSCOPE engine2 to respond to ping from other network segment.
 - Improved not to send PET alerting from BMC about the event that already 
   processed by ESMPRO/SA.
 - Improved setting of connection for  the management LAN not to be able to set 
   various port numbers to 0.
 - Improved the issue that if web server of BMC was connected by https to with 
   very unstable network connection, the status which not to be accepted 
   following http/https connection happened only occasionally.
 - Improved the issue that the monitoring of the power on redundant PSU becomes 
   not available occasionally by the low value of the power.(SDR)
 - Improved the issue that the monitoring of the FAN speed becomes not 
   available by the hotter ambient temperature.(SDR)
 - Improved to enable to use Remote KVM/Remote Media function with BMC IP 
   address which includes "255".
 - Improved the issue that Remote KVM console becomes not available only 
   occasionally by the operation with Remote KVM console which changes graphic 
   mode of the host system. (Example. refresh screen / OS shutdown) 
 - Supported the Local Monitor Lock function on a Remote KVM console.
 - Supported the Zoom Function of host system's screen on a Remote KVM console.
 - Supported the function that shows Remote Device Status on the server panel.
 - Improved the Remote Media function that to be enabled to connect two ISO 
   image simultaneously.
 - Supported the warning message about failing to run the Remote KVM console 
   applet in case of an out of JRE memory.
 - Improved the issue that the timestamp on the System Event Logs (SEL)  window 
   is shown as +1hour from actual time if the OS of the management PC was set 
   as summer time.
 - Improved the issue that  SEL/SDR/FRU/MC information windows are not 
   activated by clicking refresh icon in the Web Server function.

2009/04/24 BMCFW Revision 01.11, SDR Revision 00.08, PIA Revision 01.05
 - Initial Release.

6. Legal notices (trademarks and copyrights)

NEC Corporation and its third-party suppliers reserve the copyright to the 
Software. 
Microsoft, Windows, Windows Server, Windows Vista, BitLocker are either 
registered trademarks or trademarks of Microsoft Corporation in the United 
States and/or other countries.

All other company names and product names mentioned herein are registered 
trademarks or trademarks of their respective owners.