Release Notes for NEC Express5800/E120d-M
BMC firmware 00.15, SDR 00.05 (Offline)
===============================================================================
NEC Corporation.
May 2013

[Contents]
1.  About the software
2.  Models and software revisions for update
3.  Installation procedures
4.  Notes
5.  Revision history
6.  Legal notices (trademarks and copyrights)
--------------------------------------------------------------------------------

1.  About the software
 The NEC Express5800/E120d-M BMC firmware and SDR update module ("the software") 
supports the following functional enhancement in the NEC Express5800/E120d-M 
models:

   - Fixed the issue that the ESMPRO/SM can not detect the BMC depending on the
     network environment.
   - Fixed the issue that BMC has the pottential to stall by using remote KVM
     function after illegal BMC reset that will be caused by keeping to supply
     power to the server over half year.
     (Without using remote KVM function, BMC will not stall, only be resetted.)
     BMC reset by the BMC reset button, EXPRESSSCOPE Engine 3 Web server,
     and Command Line Interface, etc... doesn't occur this issue.
   - Revision number of BMC firmware is not displayed on "/admin/sp1/swid1"
     of the Command Line Interface.

Note:
  - To prevent a system failure, please read this document carefully and follow 
    the procedure for successful update.  Should your system malfunctions or is 
    powered off due to an unplanned event during update (for example, power 
    blackout or cutoff, lightening, and noise), the system may be damaged and 
    fails to operate normally.  In this case, any remedial measures shall be 
    taken at your expense.

2.  Models and software revisions for update 
Users who use the following server models and BMC firmware revisions need update:
 - Models to update: 
     1.  NEC Express5800/E120d-M

 - BMC firmware revision to update:

      - BMC firmware
                        BMC Firmware Revision:  00.08
                        BMC Firmware Revision:  00.09
                        BMC Firmware Revision:  00.10
                        BMC Firmware Revision:  00.12
                        BMC Firmware Revision:  00.13

     - SDR
                        SDR Revision:           00.02
                        SDR Revision:           00.03

NOTE:
If your BMC firmware and SDR revision are later than the above, you do not 
require the update(the latest revisions already include the functions to be 
added by the software).

2-1. How to confirm your BMC Firmware and SDR revision: (*1)

- By ESRAS Utility of NEC ESMPRO Agent

(1)  Run the ESRAS Utility.
(2)  Select the [Intelligent Platform Management Interface] sub menu.

 To confirm BMC Firmware revision:

(3)  Select the [Management controller information] sub menu.
(4)  Select the [Basbrd Mgmt Ctlr] sub menu.
(5)  The BMC firmware revision of your system will be displayed.

 To confirm your SDR revision:

(6)  Select the [Senosr Data Record(SDR)] and the [Repository Information] sub menu.
(7)  The SDR version of your system will be displayed.


- By BIOS Setup

(1)  Power on the system.
(2)  When the following message appears, press the F2 key to start the BIOS 
     Setup Menu. 
                         "Press <F2> SETUP"

(3)  Using the arrow keys, move the cursor to [Server]. 
(4)  Select the [System Management] sub menu and press the Enter key. 
(5)  The software revisions of your system will be displayed. 
(6)  After confirmation of the software revisions, press the ESC key and exit 
     the [System Management] sub menu. 
(7)  Move the cursor to [Exit], using the arrow keys. 
(8)  Select [Exit Discarding Changes], and exit the BIOS Setup Menu. 

- By NEC ESMPRO Manager Ver.5

(1)  Run NEC ESMPRO Manager Ver.5.
(2)  After selecting the server, select the [Remote Control] tab.
(3)  Select the [IPMI Information] sub menu.

 To confirm your BMC Firmware revision:

(4)  Select the [MC(Management Controller) Information] sub menu.
(5)  Select the [Basbrd Mgmt Ctlr] sub menu.
(6)  The BMC firmware revision of your system will be displayed.

  To confirm of SDR version

(7)  Select the [SDR-Management Information] sub menu and press the Enter key.
(8)  The SDR version of your system will be displayed.


- By EXPRESSSCOPE(R) Engine 3 Web Server function

(1)  Run EXPRESSSCOPE(R) Engine 3.
(2)  Select the [System] sub menu.
(3)  Select the [IPMI Information] sub menu.

  To confirm your BMC Firmware revision:

(4)  Select the [MC] button and select [Basbrd Mgmt Ctrl].
(5)  Check [Firmware Revision].

  To confirm of SDR version

(6)  Select the [SDR] button and select LAST Record ID / Record Type : OEMSDR
(7)  Check [[OEM Data] SDR Version].

3.  Installation procedures

- Prepare a CD-R for the update BMC firmware and SDR.

- How to copy the install CD-R:

(1) Download the update module to a desired directory.
(2) Extract the downloaded module to a desired directory.
(3) The software and its installation procedures (readme file) will be
    extracted to that specified folder.
    The folder has "NM001505W.iso" and "README_EN_Offline.TXT".
(4) Write the ISO image file to a CD-R by any CD writing program.
(5) Mark the BMC firmware and SDR versions on the media.

- How to update BMC firmware:

(1) Insert the CD-R into the optical disk drive of your system, 
    and boot the system from the CD-R.
(2) Automatically update BMC firmware and SDR using the CD-R.
    DO NOT turn off the power until the complete.
(3) After the normal complete, the following messages are displayed.

     Remove CD-R, press <Enter> key.
     The system will be powered off and on.

(4) Eject the CD-R and press enter key to boot the system.
    The system will be powered off and on automatically.
(5) Confirm that the BMC firmware Revision has been updated
    to the version listed below.

    BMC Firmware Revision  :  00.15
    SDR Revision           :  00.05

4.  Note

 4-1. Note for updating BMC firmware

      (1) Check the boot sequence of your system in order to boot 
          the disk drive of the CD-R at first.

 4-2. Note after the updated BMC firmware

      (1) Logout all web browser on your system.
      (2) Login the web browser on your system if necessary.

 4-3. Error message for updating BMC firmware

    During updating BMC Firmware, following message might be displayed.

            XXXXXXXXXXXXXXXXXXXXX................................ (*2)

            *******************************
             Error: BMCFW Update failed!!
            *******************************

    --- detailed information about (*2) ---

    (a) The image file does not support this machine.

       - Cause : The model is not a proper model.
       - Answer: Check the model and the BMC firmware version.


    (a) The image file does not support this machine.
    (b) Invalid parameter.
    (c) Failed to image file load.
    (d) The image file is corrupted.
    (e) The image file is bigger than flash rom.
    (f) Update tool does not support this firmware.
    (g) File open error. (ExUpInfo.xml)
    (h) Version info. Not exist. (ExUpInfo.xml : <version>)
    (i) Timeout was generated.

       - Cause : The update module may be broken.
       - Answer: Retry to download the update module and to update it.


    (j) Error while establishing the session.
    (k) IPMI command error. (Get Device ID)
    (l) IPMI command error. (Get FW Info)
    (m) IPMI command error. (Enter FW Update)
    (n) IPMI command error. (Upload FW Image)
    (o) IPMI command error. (Get FW Update Status)
    (p) IPMI command error. (Check FW Image)
    (q) IPMI command error. (Exec FW Update)
    (r) Update status error. (Enter FW Update)
    (s) Update status error. (Upload FW Image)
    (t) Update status error. (Check FW Image)
    (u) Firmware update error.

       - Cause : The updating BMC firmware was failed.
       - Answer: Retry to update the BMC firmware.
                 If there is the failure again, call the maintenance service.


  4-4 Error message for updating SDR
    During updating SDR, following message might be displayed.

            XXXXXXXXXXXXXXXXXXXXX................................ (*3)

            *****************************
             Error: SDR Update failed!!
            *****************************

    --- detailed information about (*3) ---

    (A) Error:====It is not a target machine of SDRupdate.
    (B) Error: Processor Check failed!!
    (C) Error: This Processor is Not Supported!!

       - Cause : The model is not a proper model.
       - Answer: Check the proper model(Processor) and the proper SDR version.


    (D) Error: Optional HDD Cage Check failed!!

       - Cause : Checking HDD cage was failed.
       - Answer: Check the connection of the HDD cage.


    (E) Can't open IPMI driver.
    (F) This SDR data is not supported.(Not Found HWID in mchk_fil)

       - Cause : The model is not a proper model.
       - Answer: Check the proper model.


    (G) Illegal parameter format.

       - Cause : parameter is not correct.
       - Answer: Retry to download the update module and to update it.


    (H) unsupported SparedSDR command on BMC.Or, the time-out is generated by 
        a system high load.

       - Cause : This BMC Firmware does not support the SDR update function.
       - Answer: After updating BMC Firmware, then reboot the system and 
                 update SDR again. 


    (I) Timeout was generated.
    (J) Get Device ID Command Error.
    (K) insufficient memory.
    (L) SDR record read error from BMC.
    (M) failed to clear the SDR repository.
    (N) failed to receive BMC response, bad completion code.
    (O) IPMI command retry error.
    (P) failed to open IPMI Driver.
    (Q) failed to send IPMI command.
    (R) IPMI comand error for Backup/GetSdrVersion.
    (S) Backup File I/O error.
    (T) SDR file does not match with what was programmed into memory.
    (U) SDR file unsuccessfully written.
    (V) It failed in retrying of MSDriver. A high load of the system is thought 
        as a cause.

       - Cause : The updating SDR was failed.
       - Answer: Retry to update SDR.
                 If there is the failure again, call the maintenance service.


5.  Revision history

2013/05/24 BMCFW Revision 00.15, SDR Revision 00.05
 - Fixed the issue that the ESMPRO/SM can not detect the BMC depending on the
   network environment.
 - Fixed the issue that BMC has the pottential to stall by using remote KVM
   function after illegal BMC reset that will be caused by keeping to supply
   power to the server over half year.
   (Without using remote KVM function, BMC will not stall, only be resetted.)
   BMC reset by the BMC reset button, EXPRESSSCOPE Engine 3 Web server,
   and Command Line Interface, etc... doesn't occur this issue.
 - Revision number of BMC firmware is not displayed on "/admin/sp1/swid1"
   of the Command Line Interface.

2013/03/26 BMCFW Revision 00.13, SDR Revision 00.05
 - Fixed the issue that it fails to restore the data of ECO Configuration
   which is backed up the initialized data.

2013/01/25 BMCFW Revision 00.12, SDR Revision 00.05
 - Supported the DC 12V Input Module. (BMCFW and SDR)
 - Fixed the issue that the retrying of SNMP alerting is only done to Alert 
   Receiver 1 in case Alert Progress setting is configured as One Alert 
   Receiver.
 - Fixed the issue that the encryption does not work on JRE7 environment
   even when Encryption of Remote KVM console in System Operation 
   Configuration is enabled.
 - Improved the threshold of voltage sensors. (SDR)

2012/12/07 BMCFW Revision 00.10, SDR Revision 00.03
 - Changed to reboot management LAN port if management LAN port does not receive
    any packet for a certain period of time.
 - Improve the character-based remote console via command line interface  of
   EXPRESSSCOPE Engine 3 to be enabled to accept mass input for example to copy
   and paste long text.
 - Improved the issue that the network functinon of EXPRESSSCOPE Engine 3 become
   unavailable by receiving Jumbo Frame Packet from Management LAN port.
 - Fixed the issue that BMC owner's events are not logged rarely after 
   BMC clear configuration by the BMC configuration Utility.
 - Supported Java 7 for web server functions of EXPRESSSCOPE Engine 3.
 - Fixed the issue that the cursor of a Linux text mode is not displayed 
   on the remote KVM console of EXPRESSSCOPE Engine 3.

2012/10/01 BMCFW Revision 00.09, SDR Revision 00.03
 - Supported Widows Server 2012 (DCMI).
 - Improved the issue that active directry user who belongs multiple group may
   be aborted to log in EXPRESSSCOPE Engine 3.
 - Improved the internal user configuration for  EXPRESSSCOPE Engine 3 to be
   disabled to change.
 - Supported the Express5800/E110d-M Japan model. (SDR 00.03)
 - Improved the Power Redundancy Sensor. (SDR)

2012/07/26 BMCFW Revision 00.08, SDR Revision 00.02
 - Initial release.


6. Legal notices (trademarks and copyrights)

All contents on this software are the copyright of NEC Corporation or the 
third-party software developer.
EXPRESSSCOPE is a registered trademark of NEC Corporation.

Microsoft, Windows, Windows Server, Windows Vista, BitLocker are either 
registered trademarks or trademarks of Microsoft Corporation in the United 
States and/or other countries.

Linux is either registered trademarks or trademarks of Linus Torvalds 
in the United States and/or other countries.

Red Hat, RPM are either registered trademarks or trademarks of Red Hat, Inc.

Miracle Linux, logo of Miracle Linux are trademarks of MIRACLE LINUX,CORPORATION.

All other company names and product names mentioned herein are registered 
trademarks or trademarks of their respective owners.