Release Notes for NEC Express5800/R120g-2E NEC Express5800/T120g
NM Firmware 3.1.3.51 , Descriptor 15020900 (Offline)
===============================================================================
NEC Corporation.
June 2019

[Contents]
1.  About the software
2.  Models and software revisions for update
3.  Installation procedures
4.  Notes
5.  Revision history
6.  Legal notices (trademarks and copyrights)
--------------------------------------------------------------------------------
1.  About the software
 The NEC Express5800/R120g-2E, NEC Express5800/T120g NM firmware update module 
 ("the software") supports the following functional enhancement.

 - Fixed the problem CPU frequency decreases and keep in high work load state
   after AC input turned ON in the server that ServerManager managed and monitored.

Note:
  - To prevent a system failure, please read this document carefully and follow 
    the procedure for successful update.  Should your system malfunctions or is 
    powered off due to an unplanned event during update (for example, power 
    blackout or cutoff, lightening, and noise), the system may be damaged and 
    fails to operate normally.  In this case, any remedial measures shall be 
    taken at your expense.

--------------------------------------------------------------------------------
2.  Models and software revisions for update 
 Users who use the following server models and NM firmware revision need update:
  - Models to update: 
     1. Express5800/R120g-2E
     2. Express5800/T120g

 - NM firmware revision to update:

   <NM Firmware>                    <Descriptor>
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14010200
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14010300
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14010400
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14010500
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14010600
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14020700
      NM Firmware Version: 3.1.3.26,   Descriptor Revision: 14020800

NOTE:
If your NM firmware revision are later than the above, you do not 
require the update(the latest revisions already include the functions to be 
added by the software).

2-1. How to confirm your NM Firmware revision:

- By BIOS Setup, to confirm your NM Firmware version and Descriptor Revision:

 (1)  Power on the system.
 (2)  When the following message appears, press the F2 key to start the BIOS 
      Setup Menu. 
                        "Press <F2> to enter SETUP"
 
 (3)  Using the arrow keys, move the cursor to [Server]. 
 (4)  Select the [System Management] sub menu and press the Enter key. 
 (5)  The software revisions of your system will be displayed. 
 
 (6)  After confirmation of the software revisions, press the ESC key and exit 
      the [System Management] sub menu. 
 (7)  Move the cursor to [Exit], using the arrow keys. 
 (8)  Select [Exit Discarding Changes], and exit the BIOS Setup Menu. 


--------------------------------------------------------------------------------
3.  Installation procedures

- Prepare a CD-R for the update NM firmware.

- How to copy the install CD-R:

(1) Download the update module to a desired directory.
(2) Extract the downloaded module to a desired directory.
(3) The software and its installation procedures (readme file) will be
    extracted to that specified folder.
    The folder has "CyG2_Desc_UpdateTool_F_15020900.iso" and "README_EN.TXT".
(4) Write the ISO image file to a CD-R by any CD writing program.
(5) Mark the NM Firmware version and descriptor revision on the media.

- How to Install NM firmware:

(1) Insert the CD-R into the optical disk drive of your system, 
    and boot the system from the CD-R.
(2) System will turn off the power once,
    and turn on the power again about 30 secconds - 2 minutes later automatically .
(3) The following messages are displayed in POST at second time power on.
    This is expected behavior no need to worry.
      "WARNING: C501 ME is in Recovery Mode."

(4) Boot the system from the CD-R again,
    Automatically update NM firmware using the CD-R(about 2 minute).
    DO NOT turn off the power until the complete.
    After the normal complete, the following messages are displayed.

      "NMFW/Descriptor Update was succeeded."
      "Please remove the CD, then press ENTER key to power cycle."

(5) Eject the CD-R and press enter key to reboot the system.
    System will turn on the power again about 30 secconds - 2 minutes later automatically .
(6) Enter to BIOS SETUP by pressing <F2> key 
    and confirm that the NM Firmware Version and Descriptor Revision
    has been updated to the version listed below.

      NM Firmware Version : 3.1.3.51
      Descriptor Revision : 15020900

--------------------------------------------------------------------------------
4.  Note

 4-1.Note for updating NM firmware

      (1) Check the boot sequence of your system in order to boot 
          the disk drive of the CD-R at first.

 4-2.Update BIOS revision to 5.0.4009 or later, before using the software.

 4-3.During updating NM Firmware, following message will display at POST screen.
     This is expected behavior no need to worry.
      "WARNING: C501 ME is in Recovery Mode."

 4-4.If ECO setting exists, it will be initialized with update.
     Please backup the setting before update,
     then restore the setting after update.

How to backup and restore ECO setting:

- By NEC ESMPRO Manager Ver.6, to backup and restore your ECO setting:
    If you have installed ESMPRO in remote environment and using it,
    you can backup and restore ECO setting by following way.
      Select Server name you want to backup/restore,
      [setting]->[backup/restore]->[backup]->[BMC setting-ECO]
      then carry out backup.
      Regarding to restore, choose [setting]->[backup/restore]->[restore]
      then carry out restore "eco.json".

- By EXPRESSSCOPE(R) Engine 3, to backup and restore your ECO setting:
    If you have installed EXPRESSSCOPE Engine in remote environment and using it,
    you can backup and restore ECO setting by following way.
      Select [setting]->[backup/restore]->[backup]
      then carry out backup [ECO(eco.json].
      Regarding to restore, choose [setting]->[backup/restore]->[restore]
      then carry out restore "eco.json".

- By Server Configuration Utility, to backup and restore your ECO setting : Windows/LinuxOS
    If you install Server Configuration Utility and using it,
    you can backup and restore ECO setting by following way.
      Select [backup/restore]->[backup]->[ECO]
      then carry out backup ECO setting.
      regarding to restore, choose [setting]->[backup/restore]->[restore]->[ECO]
      then carry out restore "eco.json".

- By Off-Line Tool, to confirm and re-set your ECO setting:
    Off-Line Tool has no function to backup and restore ECO setting.
    it is needed to perform confirmation, record, re-setting by following way.
      Power on the system.
      POST message will be displayed under a screen.
      Press <F4> key to start Off-line Tool MENU according to POST message.
      Select [Server Configuration Utility]->[ECO]->[Configuration]
      then perform confirmation, record ECO setting.
      Regarding to restore, perform re-setting by same menu.

 4-5.If "Suspended Period" is set from NEC ESMPRO/ServerManager Ver.6,
     the setting will be initialized with update.
     If you need to keep "Suspended Period setting",
     perform confirmation, record, re-setting by following way.
       Select Server name you want to confirm setting,
       [Remote Control]->[Power Management]->[ECO setting]->[Suspended Period setting]
       then perform confirmation, record Suspended Period setting before update if needed.
       then restore the setting after update.
       Regarding to restore, perform re-setting by same menu after update.

 4-6.Just after updating NM Firmware, STATUS LED lights amber, and SEL of sensor fault
     is sometimes logged, but no need worry. When this phenomenon occurred, 
     please plug out and in an AC cable.

--------------------------------------------------------------------------------
5.  Revision history

2019/06/03  NM Firmware Version: 3.1.3.51, Descriptor Revision: 15020900
 - Fixed the problem CPU frequency decreases and keep in high work load state
   after AC input turned ON in the server that ServerManager managed and 
   monitored.

2018/12/19  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14020800
 - Function change none

2018/06/13  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14020700
 - Fixed the problem CPU frequency decreases and keep in high work load state 
   in rare cases after AC input OFF for one side of redundant PSU configuration.

2018/05/07  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14010600
 - Function change none

2017/12/04  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14010500
 - Function change none

2016/12/14  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14010400
 - Function change none

2016/07/07  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14010300
 - Function change none

2016/05/10  NM Firmware Version: 3.1.3.26, Descriptor Revision: 14010200
 - Initial release.

--------------------------------------------------------------------------------
6. Legal notices (trademarks and copyrights)

All contents on this software are the copyright of NEC Corporation or the 
third-party software developer.

EXPRESSSCOPE is a registered trademark of NEC Corporation.

Microsoft, Windows, Windows Server, Windows Vista, BitLocker are either 
registered trademarks or trademarks of Microsoft Corporation in the United 
States and/or other countries.

Linux is a trademark or registered trademark of Linus Torvalds in the United 
States and other countries.
   
Red Hat and Red Hat Enterprise Linux are trademarks or registered trademarks 
of Red Hat, Inc. in the United States and other countries.

VMware is a registered trademark or trademark of VMware, Inc. in the United 
States and/or other jurisdictions.

This software uses the software under GNU General Public License or GNU Lesser 
General Public License.

All other company names and product names mentioned herein are registered 
trademarks or trademarks of their respective owners.

--------------------------------------------------------------------------------