System ROM U54 v2.84 (04/02/2026)
================================================================================
Software name    : Express5800/R120j-1M, Express5800/R120j-2M,
                   Express5800/R120j-1M (2nd-Gen),
                   Express5800/R120j-2M (2nd-Gen)
                   System ROM (BIOS) update module
Models           : Express5800/R120j-1M
                   Express5800/R120j-2M
                   Express5800/R120j-1M (2nd-Gen)
                   Express5800/R120j-2M (2nd-Gen)
Operating System : This software supports offline update and the following OS.
                   - Windows Server(R) 2019
                   - Windows Server(R) 2022
                   - Windows Server(R) 2025
                   - Red Hat(R) Enterprise Linux(R) 8
                   - Red Hat(R) Enterprise Linux(R) 9
Target Users     : See [Target Users for Update] below
Type             : System ROM
================================================================================


[About the software]
The Express5800/R120j-1M, Express5800/R120j-2M,  Express5800/R120j-1M (2nd-Gen),
Express5800/R120j-2M (2nd-Gen) System ROM (BIOS) update
 module supports the following changes in the supported models:

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.215.0 (2.84_04_02_2026).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 - For systems shipped in or after July 2026, do not install
   a System ROM version earlier than v2.84 (04/02/2026).

 Enhancements and problem fixes:
 - Enhanced the Server Asset Tag option (*1) by increasing the maximum number of
   characters that can be entered when setting the Server Asset Tag
   from 32 to 63. To configure a Server Asset Tag with 33 to 63 characters,
   you must update to iLO 6 firmware version 1.75 or later.
   If the iLO 6 firmware version is earlier than 1.75, you can configure
   a Server Asset Tag of up to 32 characters.
    (*1) System Configuration > BIOS/Platform Configuration(RBSU)
         > System Options > Server Asset Information
         > Server Information > Server Asset Tag

  ** Program and data included in this software **
 Following program and data are included in this software.
 Use one of them according to the way of installation.

  a) Flash image for System Utilities/iLO Web Interface
      firmware\U54_2.84_04_02_2026.signed.flash

  b) Executables for Windows(R)
      winx64\cp071496.exe

  c) RPM package for Linux(R)
      Linux\firmware-system-oem-u54-2.84_2026_04_02-1.1.x86_64.rpm

-------------------------------------------------------------------------------
[ Target Users for Update ]
This software is available for the users who use the following models with the
following System ROM version.

  - Models to be supported

     1. Express5800/R120j-1M
     2. Express5800/R120j-2M
     1. Express5800/R120j-1M (2nd-Gen)
     2. Express5800/R120j-2M (2nd-Gen)

  - System ROM Versions to be supported

     1. U54 v1.32 (03/23/2023)
     2. U54 v1.46 (09/26/2023)
     3. U54 v2.16 (03/01/2024)
     4. U54 v2.32 (09/09/2024)
     5. U54 v2.44 (01/17/2025)
     6. U54 v2.60 (08/07/2025)
     7. U54 v2.72 (11/27/2025)

Note: In case of using newer System ROM from the above version, it has already
      applied equivalent enhancements. Updating the System ROM isn't needed.

Be sure to check the System ROM version and date with the following procedures.
Select an arbitrary procedure and check the version before and after the update.

 ** System Utilities **

 You can check the System ROM version and date by the following procedure.

    1. Power on the system and the contents of process by POST (Power On Self-
       Test) will be shown on the screen. After a short time, the following
       message is shown. Press <F9> key, "System Utilities" is started.

                        [F9] System Utilities

    2. After starting "System Utilities", select "System Information".

    3. Select "Firmware Information".

    4. Each firmware version is shown on the screen. The System ROM version and
       date can be seen at "System ROM" option.

  Note: After checking the System ROM version, press the <ESC> key or
        select "Exit" to exit the System Utilities.

  Note: About detail of "System Utilities" usage, refer to "1. System
        Utilities" section in the chapter of "Useful Features" of the
        maintenance guide.

 ** Windows(R) OS **

 You can check the System ROM date by a following procedure.

    1. Hold down <Windows> key and press <R> key.

    2. In the "Run" dialog box, type "msinfo32" and then click "OK".

    3. After "System Information" has started, select "System Summary".

    4. Check the System ROM version by the profile of "BIOS Version/Date".

 ** Linux(R) OS **

 You can check the System ROM date by a following procedure.

    1. Launch the terminal such as xterm.

    2. Execute the command as follows.

        # /usr/sbin/dmidecode | less

        Note: "#" means prompt. You do not need to input "#".

    3. Check the System ROM date by "BIOS Information->Release Date".

    Note: The dmidecode command has to be installed.

================================================================================
 System ROM Installation Procedure
================================================================================

 ** System Utilities **

 [ Preparation ]
  - USB memory x1

  1. Preparation of flash image (*.flash)
   (1) Prepare the USB memory that is formatted with FAT or FAT32.
   
   (2) Copy "a) Flash image for System Utilities/iLO Web Interface file"
       (approx. size 32MB) to a USB memory.

  2. System ROM installation procedure
     Install the System ROM by a following procedure.

   (1) Attach the USB memory created in the procedure of "1" and power on the
       system.

   (2) In POST, press <F9> key to enter System Utilities.
   
   (3) Select "Embedded Applications > Firmware Update > System ROM" menu.

   (4) Choose "Select Firmware File", and then select the device in which flash
       image was copied.
   
   (5) Select flash image (i.e. *.flash).

   (6) Select "Start Firmware Update".

   (7) When the popup message of "Press ENTER to start firmware update.
       This process might take a few minutes..." is shown, press <ENTER> key.
       Update process is started.

   (8) The progress of the update is shown. When it's completed, the popup
       message of "Firmware update completed successfully." is shown. Press
       <ENTER> key, the message is closed.

   (9) Detach the Installation USB memory from the system.
   
   (10) Reboot the system; Select the "Reboot the System" option at top
        level menu of System Utilities.

   (11) Wait reboot completion for update to take effect.

     The installation is successfully finished.

 ** iLO Web Interface **

  1. Preparation of flash image (*.flash)

   (1) Copy "a) Flash image for System Utilities/iLO Web Interface file"
       (i.e. *.flash) to any location which is accessible from the remote PC.

  2. System ROM installation procedure

   (1) Start the Web Browser on remote PC. And log-in to the iLO Web 
       Interface by a "Configure to iLO Settings" privilege user.

   (2) Select "Firmware & OS Software tab" from the right menu.

   (3) Select "Update Firmware" from the left menu.

   (4) Select the flash image, copied by a procedure of "1."

   (5) Press "Flash" to begin update process.

   (6) Wait for the "Firmware Update Completed." message to display.

   (7) Reboot the system.

   (8) Wait reboot completion for update to take effect.

     The installation is successfully finished.

 ** Windows(R) OS **

  1. Preparation of Installation

   (1) Log on to the system as a user with administrator privilege.

   (2) Terminate all running application.

   (3) Copy "b) Executables for Windows(R) file" to a suitable
       folder.

  2. System ROM installation procedure

   (1) Double-click "b) Executables for Windows(R) file" (i.e. *.exe).
       The System ROM Update Program will start.

   (2) Follow the messages will be shown and complete the operation.

   (3) If the messages requesting reboot will be shown, select "yes" to reboot
       of the system.

   (4) Wait reboot completion for update to take effect.
       
     The installation is successfully finished.

 ** Linux(R) OS **

  1. Preparation of Installation

   (1) Log-in as root. Or switch to root with "su" command.

   (2) Terminate all running application.

   (3) Copy "c) RPM package for Linux(R) file" to a suitable directory.

       e.g. /root 

  2. System ROM installation procedure

    (1) Install the RPM package of this System ROM update module by the command
       below.

        # rpm -Uvh <filename>.rpm

        Note: The "<filename>.rpm" should replace to RPM package name which
              is described at above "Binaries of this release" section.

        Note: "#" means prompt. You do not need to input "#".
 
   (2) See where the files land by the command below.

        # rpm -qlp <filename>.rpm

   (3) Change to the directory you see in the previous step.

   (4) Run setup by the command below.

        # ./setup

   (5) Follow the messages will be shown and complete the operation.

   (6) If a reboot inquiry is appear then press "y" to trigger reboot.

   (7) Wait reboot completion for update to take effect.
        
      The installation is successfully finished.

 ** Other OSes (e.g. VMware(R), etc.) **
 Use the one of following procedures to update:
 - Install the System ROM from System Utilities
 - Install the System ROM from iLO Web Interface

================================================================================
 Notes
================================================================================
  ** Notes in general **

  * Refer to "license_en.txt" about the user license agreement.

  * When you install the system ROM, the flashing mechanism writes over the
    backup ROM and saves current ROM as a backup, enabling you to switch easily
    to the alternate ROM version if the new ROM becomes corrupted for any
    reason. This feature protects the existing ROM version, even if you
    experience a power failure while flashing the ROM.

  * When Windows(R) BitLocker(TM) function is set to "Enabled", install the
    System ROM after making the function "Disabled". Then make the function
    "Enabled" after install and reboot of the system. If you install the system
    ROM without making the function "Disabled", you may need the recovery
    password when you boot the system.

  * This software does not support a virtualized environment such as hyper
    visor, guest OS, etc. Please install either on the OS which this software
    supports or with the method of offline installation.

  * To meet firmware dependencies, you can update iLO6 firmware by latest
    Starter Pack. 
    You can download latest update module(s) from the following web site.
    https://www.nec.com/express
    ("Support & Downloads" of the page top - PCs & Servers - Servers - Downloads
    - Select Model)

  ** Note for Windows(R) OS environment and Linux(R) OS environment **

  * This software will access to Baseboard Management Controller(iLO6). It is
    required that the "iLO 6 Channel Interface Driver" (CHIF) must be installed.
    The CHIF driver can be installed by using EXPRESSBUILDER or "Starter Pack".


--------------------------------------------------------------------------------
[Revision history]
Version: v2.84 (04/02/2026)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.215.0 (2.84_04_02_2026).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 - For systems shipped in or after July 2026, do not install
   a System ROM version earlier than v2.84 (04/02/2026).

 Enhancements and problem fixes:
 - Enhanced the Server Asset Tag option (*1) by increasing the maximum number of
   characters that can be entered when setting the Server Asset Tag
   from 32 to 63. To configure a Server Asset Tag with 33 to 63 characters,
   you must update to iLO 6 firmware version 1.75 or later.
   If the iLO 6 firmware version is earlier than 1.75, you can configure
   a Server Asset Tag of up to 32 characters.
    (*1) System Configuration > BIOS/Platform Configuration(RBSU)
         > System Options > Server Asset Information
         > Server Information > Server Asset Tag

Version: v2.80 (01/29/2026)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.215.0 (2.80_01_29_2026).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.
   This version mitigates security vulnerability of CVE-2025-31648.

 - Addressed following security vulnerabilities.
    CVE-2025-35991, CVE-2025-30513, CVE-2025-31944, CVE-2025-32007,
    CVE-2025-32467, CVE-2025-27572, CVE-2025-27940

 - Addressed an issue where system could run into high CPU utilization and
   unresponsiveness when processing specific corrected error events.

 - Addressed an issue where root ports were improperly configuring 10-bit TLP
   tags in PCIe devices that only support 8-bit tags, causing completion
   timeouts and device communication failures.

Version: v2.72 (11/27/2025)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.204.0 (2.72_11_27_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed an issue where the system might report Memory Uncorrectable Error
   during booting up when setting Memory Clear on Warm Reset option(*1)
   to Enabled.
    (*1) System Configuration > BIOS/Platform Configuration (RBSU) 
         > System Options ＞ Boot Time Optimizations

Version: v2.70 (10/31/2025)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.204.0 (2.60_08_07_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.

 - Addressed following security vulnerabilities.
    CVE-2025-22885

 - Addressed an issue where the Virtual Floppy or Virtual Folder may not
   function properly when using HTML5 IRC mode.

 - Addressed an issue where the system time zone setting may not update as
   expected.

 - Addressed an issue where the system might unexpectedly report unsupported
   DIMM configurations when system includes full DIMM population.

 - Addressed an issue where the system remote console may become unresponsive
   when the EXPRESSBUILDER warning message appears.

 - Addressed an issue where the negotiated PCIe link width might be incorrect
   when the PCIe Slot XX Bifurcation option was set to Bifurcate or
   Dual Bifurcate in the PCIe Bifurcation Options menu (*1).
    (*1) System Configuration > BIOS/Platform Configuration (RBSU) 
         > PCIe Device Configuration > Advanced PCIe Configuration
         > PCIe Bifurcation Options

Version: v2.60 (08/07/2025)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.204.0 (2.60_08_07_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed following security vulnerabilities.
    INTEL-SA-01280

 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.
   This version mitigates security vulnerability of INTEL-SA-01312,
   INTEL-SA-01313.

 - Added new UMONITOR option in Processor Options menu(*1).
    (*1) System Configuration > BIOS/Platform Configuration (RBSU)
         > Processor Options

 - Added new CPU C1 Auto Demotion option and CPU C1 Auto Undemotion option 
   in Power and Performance options menu(*2).
    (*2) System Configuration > BIOS/Platform Configuration (RBSU)
         > Power and Performance Options

 - Added new Uncore Frequency RAPL option in Power and Performance Options
   menu(*3).
    (*3) System Configuration > BIOS/Platform Configuration (RBSU)
         > Power and Performance Options

 - Added support for the CPU board (N8101-1896).

 - Addressed an issue where the system RBSU setting change might not take
   effect when the System ROM is being updated.

 - Addressed an issue where the system might not be able install server profile
   when boot option is enabled for MR RAID Controller.

 - Addressed an issue where System Utilities might hang during operation
   when the language is set to Japanese or Chinese.

Version: v2.50 (04/22/2025)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.89.0 (2.50_04_01_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.
   This version mitigates security vulnerability of INTEL-SA-01244, 
   INTEL-SA-01247, INTEL-SA-01249.
 
 - Added help text for "Smooth Cooling" in Thermal Configuration option(*1).
    (*1) System Configuration > BIOS/Platform Configuration (RBSU)
         > Advanced Options > Fan and Thermal Options > Thermal Configuration

 - Addressed an issue where the Name field of the Logical Drive under
   MR controller page might be missing or changed unintentionally after
   exiting and going back to the MR controller page.

 - Addressed an issue where the Intel PCH model name might be unknown
   in System information(*2).
    (*2) System Information > Summary

Version: v2.48 (03/11/2025)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.75.0 (2.44_01_17_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed an issue where the system might RSOD when performing firmware
   update via Firmware Management Protocol.

Version: v2.46 (02/21/2025)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.75.0 (2.44_01_17_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Added pop-up message for all EXPRESSBUILDER boot paths to warn users of
   the risk of data loss.

 - Addressed an issue where the system might RSOD when both TXT and TDX are
   enabled.

 - Addressed an issue where the system might fail to update NVMe drive firmware.

Version: v2.44 (01/17/2025)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.75.0 (2.44_01_17_2025).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed following security vulnerabilities.
   CVE-2024-37020

 - Addressed an issue where the system would use UUID for IPV6 DHCP when the
   IPv6 DHCP Unique Identifier option(*1) is set to DUID-LLT.
    (*1) System Configuration > BIOS/Platform Configuration(RBSU)
        > Network Options > Network Boot Options
        > IPv6 DHCP Unique Identifier

 - Addressed an issue where the system Consistent Device Naming (CDN) is not
   working in Windows Server.

 - Addressed an issue where the system memory address translation did not match
   with system limitation.

 - Addressed an issue where the system might bring up a warning message ("ERST:
   [Firmware Warn]: too many record IDs!") in the Linux OS environment during
   boot up.

 - Addressed an issue where the Maximum Uncore Frequency/Minimum Uncore
   Frequency options(*2) were not set to their default values after restoring
   default settings.
    (*2) System Configuration > BIOS/Platform Configuration (RBSU) 
         > Power and Performance Options
         > Maximum Uncore Frequency/Minimum Uncore Frequency

 - Addressed an issue where the system fan speed remained above 40% when the
   OCP cable is connected without an OCP device installed.

Version: v2.42 (12/06/2024)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.75.0 (2.42_12_06_2024).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Updated the boot device string rules.

 - Added a new "Smooth Cooling" parameter of Thermal Configuration(*1) option
   to Fan and Thermal Options menu.
    (*1) System Configuration > BIOS/Platform Configuration(RBSU)
         > Fan and Thermal Options > Thermal Configuration

 - Addressed an issue where the system might detect memory uncorrectable errors
   when the Minimum Processor Idle Power Core C-State option(*2) is set to
   C6 State and the system has been idle for an extended period of time.
    (*2) System Configuration > BIOS/Platform Configuration (RBSU)
         > Power and Performance Options
         > Minimum Processor Idle Power Core C-State

 - Addressed an issue where the system might hang during memory initialization
   after using the Restore Default Manufacturing Settings option to restore
   factory settings.

 - Addressed an issue where system RBSU menu might list duplicate or incorrect
   network interfaces in the selection page.

 - Addressed an issue where the system RBSU menu might not display clear drive
   location information.

 - Updated the Intelligent Platform Abstraction Data.

 - Addressed an issue where systems with two DIMMs installed per memory channel
   might reboot unexpectedly, stop responding during DIMM initialization, or log
   Uncorrectable Machine Check Exceptions (UMCEs) during periods of intense
   memory use.

Version: v2.40 (11/08/2024)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.

 Notes:
 - This version of the System ROM should be paired with
   Server Platform Services (SPS) Firmware 6.1.4.75.0 (2.40_10_23_2024).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.
   This version mitigates security vulnerability of CVE-2024-36293,
   CVE-2024-28047, CVE-2024-39279, CVE-2024-31157, CVE-2024-31068.

 - Added new IML messages to indicate the status of NVMe secure erase and AMT.

 - Added a new HardwarePM Interrupt option to the  Advanced Power Options(*1)
   menu.
    (*1) System Configuration > BIOS/Platform Configuration (RBSU)
         > Power and Performance Options > Advanced Power Options
         > HardwarePM Interrupt

 - Addressed an issue where the "Server Boot Order" in iLO web interface was not
   aligned with "UEFI Boot Order Control"(*2) in RBSU.
    (*2) System Configuration > BIOS/Platform Configuration (RBSU)
         > Boot Options > UEFI Boot Settings > UEFI Boot Order Control

 - Addressed an issue where the system might be asserted when plugging in
   RAID Controller (MR, 8GB, RAID 0/1/5/6, PCI)[N8103-252].

 - Addressed an issue where an error message in Linux would indicate TCG log
   size is not compatible.

 - Addressed an issue where incorrect drive location information would be shown.

 - Addressed an issue where the system displays the warning "Cooling Unit 1
   Fans" Redundancy Lost in VMware ESXi operating systems.

 - Addressed an issue where a red circle could appear next to "Changes Pending"
   at the bottom of the screen, even if no optional settings were changed
   in RBSU.

Version: v2.34 (10/04/2024)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with 
   Server Platform Services (SPS) Firmware 6.1.4.47.0 (2.20_03_26_2024).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed an issue where the firmware version and status in the device
   inventory on the iLO Web interface may display incorrectly when the PCIe
   Slot XX Bifurcation option(*1) in the PCIe Bifurcation Options menu is set to
   Bifurcate or Dual Bifurcate. (X: changes depending on the installed slot,
   such as 1, 2, 3...)
    (*1) System Configuration > BIOS/Platform Configuration (RBSU)
         > PCIe Device Configuration > Advanced PCIe Configuration
         > PCIe Bifurcation Options

 - Addressed an issue where the product name information in Device Inventory of
   iLO web may show unknown or blank for M.2 drives.

 - Fixed an issue where the iLO 6 firmware version may show incorrectly.

 - Addressed an issue where NUMA node assignments might not be evenly distributed
   among PCI slots when the Virtual NUMA option(*2) is set to Enabled.
    (*2) System Configuration > BIOS/Platform Configuration (RBSU)
         > Memory Options > Virtual NUMA

Version: v2.32 (09/09/2024)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with 
   Server Platform Services (SPS) Firmware 6.1.4.47.0 (2.20_03_26_2024).

 - When iLO 6 firmware version 1.64 or later is applied, the "Executables for
   Windows(R)" or the "RPM package for Linux(R)" cannot be used to change
   the System ROM to versions prior to v2.32. To change the System ROM to
   a version prior to v2.32, please use the "Flash image for System Utilities
   /iLO Web Interface".

 Enhancements and problem fixes:
 - Addressed an issue where One button secure erase (OBSE) report may show
   incorrect Drive Port Number and Box Number for SR RAID controller.

 - Addressed an issue where system may become stuck after enrolling many
   certificates and signatures.

Version: v2.30 (08/09/2024)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with 
   Server Platform Services (SPS) Firmware 6.1.4.47.0 (2.20_03_26_2024).

 Enhancements and problem fixes:
 - Addressed an issue where duplicated and incorrect task status were logged
   iLO Event Log.

 - Addressed an issue where the Negotiated Link Width of the PCIe was
   not displayed correctly when the PCIe Slot XX Bifurcation option was set to
   "Bifurcate" or "Dual Bifurcate".
 
 - Addressed an issue where system may encounter RSOD after enrollment of an
   improper certificate.

 - Addressed an issue where the Logical Drive name was cleared in RBSU after
   leaving the configuration page of MR controllers.

 - Addressed an issue that Battery Failure IML message log may be incorrectly
   logged for RAID Controller with Flash Backup Unit [N8103-218].

 - Addressed an issue where 480GB SSD Adapter for OS Boot (RAID 1)[N8103-247]
   may not be identified as an NVMe device.

 - Addressed an issue where the driver Health Message was shown twice in POST
   when drive was removed and ran cold boot.

Version: v2.22 (06/19/2024)

Upgrade Requirement: Critical - Update to this version immediately.

 Notes:
 - This version of the System ROM should be paired with 
   Server Platform Services (SPS) Firmware 6.1.4.047.0 (2.20_03_26_2024).

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.

 - Addressed an issue where a NVMe drive would not be unmounted when it
   exceeds the DPC error threshold with ESXi 8.0u2 or newer versions.

 - Addressed an issue where system would not be configured as 4 sub-NUMA nodes
   per socket (SNC4) when Virtual NUMA option is enabled and SNC2 is enabled.

Version: v2.20 (05/27/2024)

Upgrade Requirement: Recommended 
                     - Update to this version at your earliest convenience.
 Notes:
 - When system updated to System ROM v2.12 (12/13/2023) or later, it should be
   updated Server Platform Services(SPS) Firmware 06.01.04.005.0 or later at
   the same time.

 Enhancements and problem fixes:
 - Updated microcode for Intel(R) Xeon(R) Scalable Processor family.

 - Addressed following security vulnerabilities.
   CVE-2023-5678, CVE-2024-0727, CVE-2021-38578, CVE-2023-45229.

 - Added a new "C6 without C1E" parameter of Minimum Processor Idle Power Core
   C-State(*1) option to Power and Performance Options menu.
    (*1) System Configuration > BIOS/Platform Configuration(RBSU)
         > Power and Performance Options
         > Minimum Processor Idle Power Core C-State

 - Added a new Intel(R) AVX License Pre-Grant Override option to the
   Advanced Performance Tuning Options(*2) menu.
    (*2) System Configuration > BIOS/Platform Configuration(RBSU)
         > Power and Performance Options > Advanced Performance Tuning Options

 - Added a new Intel(R) AVX ICCP Pre-Grant Level option to the
   Advanced Performance Tuning Options(*3) menu.
    (*3) System Configuration > BIOS/Platform Configuration(RBSU)
         > Power and Performance Options > Advanced Performance Tuning Options

 - Added a new PCI-E ASPM Support (Global) option to the
   Advanced PCIe Configuration(*4) menu.
    (*4) System Configuration > BIOS/Platform Configuration(RBSU)
         > PCIe Device Configuration > Advanced PCIe Configuration

 - Addressed an issue where system failed to boot with selected Hard Disk Drive
   by setting One-Time Boot Option in iLO web interface.

 - Addressed an issue where pressing the <F12> key and selecting [Save and Exit]
   in the UEFI Boot Order(*5) menu unexpectedly clears the boot order.
    (*5) System Configuration > BIOS/Platform Configuration(RBSU)
         > Boot Options > UEFI Boot Settings > UEFI Boot Order

 - The default value of the Current TPM 2.0 Active PCRs option (*6) has been
   changed to "SHA1 and SHA256" parameter.
    (*6) System Configuration > BIOS/Platform Configuration(RBSU)
         > Server Security > Trusted Platform Module Options

 - Addressed an issue where Redfish resource was not updated after deleting
   secure boot keys via System Configuration (RBSU).

 - Addressed an issue where the OS could not detect the iSCSI drive through
   IPv6 installation when iSCSI IP Address Type(*7) option is set to Auto.
   (*7) System Configuration > BIOS/Platform Configuration(RBSU)
        > Network Options > iSCSI Configuration > Add an iSCSI Attempt
        > (NIC Adapter name)

 - Addressed an issue where the boot order of NVMe drives cannot be changed.

 - Addressed an issue where a RSoD might occur during the update of
   SAS drive firmware using Starter Pack. 

Version: v2.16 (03/01/2024)

 Notes:
 - When system updated to System ROM v2.12 (12/13/2023) or later, it should be
   updated Server Platform Services(SPS) Firmware 06.01.04.005.0 or later at
   the same time.

 Enhancements and problem fixes:
 - This version mitigates a security vulnerability (CVE-2022-36763,
   CVE-2022-36764) in TPM2 Measure boot library.

 - This version mitigates a security vulnerability (CVE-2023-45853)
   in MiniZip library.

 - This version mitigates a security vulnerability (CVE-2023-45229,
   CVE-2023-45230, CVE-2023-45231, CVE-2023-45232, CVE-2023-45233,
   CVE-2023-45234, CVE-2023-45235, CVE-2023-45236, CVE-2023-45237)
   in EDK2 NetworkPkg IP stack implementation.

 - Addressed an issue where PCI slot information, Slot Physical width and
   Slot Pitch are not correct in the SMBIOS Type 9.

 - Addressed an issue where the NUMA nodes are not assigned properly when
   Sub-NUMA Clustering(*) option is set Enable SNC2 (2-clusters) or
   Enable SNC4 (4-clusters).
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Power and Performance Options 
        > Sub-NUMA Clustering

 - Addressed an issue where the operating system cannot detect
   the iSCSI hard drive through IPv6 installation.

 - Addressed an issue where the version information of
   the System Programmable Logic Device may be displayed incorrectly in RBSU and
   iLO web interface.

 - Addressed an issue where a Red Screen of Death (RSOD) may be seen during
   a system boot.

 - Addressed an issue where the Enabled Cores per Processor(*) option in RBSU
   cannot be set greater than 56.
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Processor Options > Enabled Cores per Processor

Version: v2.12 (12/13/2023)

 Notes:
 - When system updated to System ROM v2.12 (12/13/2023) or later, it should be
   updated Server Platform Services(SPS) Firmware 06.01.04.005.0 or later at
   the same time.

 Enhancements and problem fixes:

 - Addressed an issue where Intel(R) Software Guard Extensions (SGX) Attestation
   may fail on the 5th Generation Intel(R) Xeon(R) Scalable Processors.
   Software Guard Extensions (SGX) is disabled by default.

Version: v2.10 (11/28/2023)

 Enhancements and problem fixes:

 - Supported Express5800/R120j-1M(2nd-Gen)[N8100-3006Y/3007Y] and 
   Express5800/R120j-2M(2nd-Gen)[N8100-3008Y/3009Y/3010Y/3011Y/3012Y].
 
 - Added a new "5600 MHz" and "5200 MHz" parameters of
   Maximum Memory Bus Frequency(*) option to Memory Options menu. 
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Memory Options > Maximum Memory Bus Frequency

 - Added a new Filter Non-bootable Drives option to the Boot Options(*) menu.
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Boot Options > Filter Non-bootable Drives

 - Enhanced the warning messages of "Embedded SATA Configuration" options in
   RBSU.

 - Added a new Trust Domain Extension (TDX) option and
   TDX Secure Arbitration Mode Loader (SEAM Loader) option to
   the Intel Security Options(*) menu. 
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Server Security > Intel Security Options

 - Added a new Disable excluding Mem below 1MB in CMR option and
   TME-MT/TDX key split option to the Intel Security Options(*) menu.
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > Server Security > Intel Security Options

 - Added a new PCIe Data Link Feature option to
   the Advanced PCIe Configuration(*) menu. 
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > PCIe Device Configuration > Advanced PCIe Configuration

 - Added PCIe Gen2 device in SMBIOS type 9.

 - Addressed an issue where PCIe fatal error reporting function did not respond
   correctly.

 - Addressed an issue where Intel(R) TSX Support(*) option could not be set with
   enabled state.
     (*)System Configuration > BIOS/Platform Configuration(RBSU) 
         > Processor Options > Intel(R) TSX Support

 - Addressed an issue where the x2APIC is not enabled for 64-core processors.

 - Addressed an issue where the PCIe correctable error message was not displayed
   in Integrated Management Log (IML).

 - Addressed an issue where system might hang while accessing IML logs from
   System Utilities.

Version: v1.48 (10/19/2023)

 Enhancements and problem fixes:
 - Replaced "AC power" with "external power" in the help text of
   "Automatic power-on" option.
    (*) System Configuration > BIOS/Platform Configuration(RBSU) 
        > System Options > Server Availability 
        > Automatic power-on

 - Addressed an issue where system might hang with SRIS of CPU PCIe port
   enabled.

Version: v1.46 (09/26/2023)

 Enhancements and problem fixes:
 - Addressed an issue where the RAID Controller(N8103-248, N8103-249, N8103-250,
   N8103-251, N8103-252) status is displayed as "unknown"
   on the iLO Web Interface.

Version: v1.44 (07/31/2023)

 Enhancements and problem fixes:
 - Address an issue with certain 4th Generation Intel(R) Xeon(R) Scalable 
   Processors(*) that can result in an unexpected reset with a machine check
   error logged to the Integrated Management Log (IML). 
    (*) Excluding Platinum, Gold (64XX), Silver (44XX), and Bronze (34XX) are
        target.

Version: v1.40 (06/29/2023)

 Enhancements and problem fixes:
 - Addressed an issue where a drive cannot be unmounted after hot-plug 
   interruption during DPC (Downstream Port Containment) recovery process
   under VMware ESXi.

 - Addressed an issue where the system would hang in POST when
   "Intel UPI link Enablement" option(*) was set to "Single Link Operation".
    (*) System Configuration > BIOS/Platform Configuration(RBSU)  
        > Power and Performance Options > Intel UPI Options 
        > Intel UPI Link Enablement

 - Addressed an issue where the SMBIOS type 38 offset 0x10 had an incorrect 
   value.

 - Addressed an issue where the erase status for SATA drives is reported 
   incorrectly when using One Button Secure Erase.

 - Addressed an issue where location information under System Utilities
   "Storage Device Information" menu will show null string when
   "Embedded SATA Configuration" option was set to "Intel VROC SATA Support".

 - Addressed an issue where the "Minimum Processor Idle Power Core C-state" 
   option from RBSU showed an incorrect value when "Workload Profile" option is
   set to "Virtualization - Max Performance", "Low Latency",
   "Transactional Application Processing", or "High Performance Compute (HPC)".

 - Addressed an issue where the TPM status between RBSU and iLO web interface 
   were not synchronized.

 - Addressed an issue where an incorrect "processor's PUcode" version showed up
   on screen during the POST after downgrading the System ROM.

 - Addressed an issue where status display of PCIe Root Complex for
   Intel Quick Assist Technology (Intel QAT) is not correct in
   Windows Device Manger on dual-processor systems.

 - Addressed an issue where the PCI speed might be incorrect when setting
   "Maximum PCI Express Speed" option to "Per Port Control".

 - Addressed an issue where the UMCE may occur during peer-to-peer data 
   transaction startup, causing shutdown or restart, when multiple
   NVIDIA A16 [N8105-66] GPU computing cards are installed.

Version: v1.32 (03/23/2023)

 - Initial release.

--------------------------------------------------------------------------------
[Copyright and Trademark]

All contents on this software are the copyright of NEC Corporation or the
third-party software developer. All other contents mentioned herein are
copyright of their respective owners.

Microsoft, Windows, Windows Server are trademarks or registered trademarks of
Microsoft Corporation in the United States and other countries.
Linux(R) is a registered trademark of Linus Torvalds in the United States and
other countries.
Red Hat is a trademark or a registered trademark of Red Hat Inc. in the United
States and other countries.

All other company names and product names mentioned herein are registered
trademarks or trademarks of their respective owners.

--------------------------------------------------------------------------------
   Copyright NEC Corporation 2026